FIPA Service Hotline

00 800 - 22 553 472

Guide blocks

Guide gripper components onto workpieces with extreme precision in tight quarters: FIPA double-acting guide blocks excel at tasks involving small workpieces and sensor nuts for the optional monitoring of the piston position.


Guide blocks - double-acting

High precision combination of cylinder and linear guiding
guide-block-fipa-gr0711025 Enlarge picture
Combination of guide block and dual-piston cylinder
  • Unit to precisely guide gripper components such as sprue grippers or nippers to the workpiece
  • Double-acting, separate compressed air connections for extraction and rectraction
  • Sensors for optional detection of piston position (extracted / retracted)

Technical data

Item no.GR07.208-30GR07.208-50GR07.208-75GR07.220-30GR07.220-50GR07.220-75GR07.220-100GR07.220-10GR07.220-30GR07.220-50GR07.220-75GR07.220-125GR07.220-150
Compressed air connection 2xM5 2xM5 2xM5 2xG1/8 2xG1/8 2xG1/8 2xG1/8 2xG1/8 2xG1/8 2xG1/8 2xG1/8 2xG1/8 2xG1/8
Operating pressure [bar] 1.5 - 7 1.5 - 7 1.5 - 7 1.5 - 7 1.5 - 7 1.5 - 7 1.5 - 7 1.5 - 7 1.5 - 7 1.5 - 7 1.5 - 7 1.5 - 7 1.5 - 7
Piston diameter [mm] 8 8 8 20 20 20 20 20 20 20 20 20 20
Lift [mm] 30 50 75 30 50 75 100 10 30 50 75 125 150
Medium Filtered and oiled / unoiled air Filtered and oiled / unoiled air Filtered and oiled / unoiled air Filtered and oiled / unoiled air Filtered and oiled / unoiled air Filtered and oiled / unoiled air Filtered and oiled / unoiled air Filtered and oiled / unoiled air Filtered and oiled / unoiled air Filtered and oiled / unoiled air Filtered and oiled / unoiled air Filtered and oiled / unoiled air Filtered and oiled / unoiled air
Operating temperature [°C] -5 - 60 -5 - 60 -5 - 60 -5 - 60 -5 - 60 -5 - 60 -5 - 60 -5 - 60 -5 - 60 -5 - 60 -5 - 60 -5 - 60 -5 - 60
Weight [g] 190 285 410 1,010 1,250 1,630 2,150 1,010 1,010 1,250 1,630 2,670 3,190
Data Sheet Download datasheet Download datasheet Download datasheet Download datasheet Download datasheet Download datasheet Download datasheet Download datasheet Download datasheet Download datasheet Download datasheet Download datasheet Download datasheet
CADCAD downloadCAD downloadCAD downloadCAD downloadCAD downloadCAD downloadCAD downloadCAD downloadCAD downloadCAD downloadCAD downloadCAD downloadCAD download
Quote Quote Quote Quote Quote Quote Quote Quote Quote Quote Quote Quote Quote Quote

+Ordering notes

  • Lift adjusters available on request
  • PNP and NPN sensors:
    - C-slot (90° angle): GR04.202P, GR04.202N
    - C-slot (straight, short design): GR04.280P, GR04.280N

+Notes

  • Linear guide blocks can also be used to move gripped workpieces more closely together, to prepare the items for example for pick and place by vacuum grippers

+Dimensions

BDD_GR07.208-75

GR07.208-30, GR07.208-50, GR07.208-75

BDD_GR07.220-100

GR07.220-30, GR07.220-50, GR07.220-75, GR07.220-100, GR07.220-10, GR07.220-30, GR07.220-50, GR07.220-75, GR07.220-125, GR07.220-150

Item no.GR07.208-30GR07.208-50GR07.208-75GR07.220-30GR07.220-50GR07.220-75GR07.220-100GR07.220-10GR07.220-30GR07.220-50GR07.220-75GR07.220-125GR07.220-150
A [mm]72108158971221612149797122161268320
F [mm]13202715151937151515194119
G [mm]20232845353535454535353844
J [mm]40385050506070505050607080
M [mm]3452345223467
N [mm]4664666446688

+Theoretical cylinder force depending on the working pressure

+Accessories


NEW

Guide blocks, extra narrow design - double-acting

  • Unit to precisely guide gripper components such as sprue grippers or nippers to the workpiece
  • Extra narrow construction for space-saving assembly
  • Optional position monitoring through detection of piston position

Technical data

Item no.GR07.506-10GR07.506-20GR07.506-30GR07.510-10GR07.510-20GR07.510-30GR07.516-10GR07.516-20GR07.516-30
Principle of operation Double-acting Double-acting Double-acting Double-acting Double-acting Double-acting Double-acting Double-acting Double-acting
Piston diameter [mm] 6 6 6 10 10 10 16 16 16
Lift [mm] 10 20 30 10 20 30 10 20 30
Piston speed [mm/sec] 50 - 500 50 - 500 50 - 500 50 - 500 50 - 500 50 - 500 50 - 500 50 - 500 50 - 500
Operating temperature [°C] -5 - 60 -5 - 60 -5 - 60 -5 - 60 -5 - 60 -5 - 60 -5 - 60 -5 - 60 -5 - 60
Weight [g] 70 80 100 125 150 170 230 260 290
Operating pressure [bar] 1.2 - 7 1.2 - 7 1.2 - 7 1.2 - 7 1.2 - 7 1.2 - 7 1.2 - 7 1.2 - 7 1.2 - 7
Data Sheet Download datasheet Download datasheet Download datasheet Download datasheet Download datasheet Download datasheet Download datasheet Download datasheet Download datasheet
CADCAD downloadCAD downloadCAD downloadCAD downloadCAD downloadCAD downloadCAD downloadCAD downloadCAD download
Quote Quote Quote Quote Quote Quote Quote Quote Quote Quote

+Ordering notes

  • Extension cables for sensors:
    - 20.503: 3-Pole M8, straight, length 2,500 mm, open wire
    - 20.507: 3-Pole M8, straight, length 2,000 mm, open wire
    - 20.570: 3-Pole M8, length 1,500 mm, end with plug 3-Pole M8
  • PNP and NPN sensors:
    - C-slot (90° angle): GR04.202P, GR04.202N
    - C-slot (straight, short design): GR04.280P, GR04.280N
  • Other lifts available on request

+Dimensions

BDD_GR07.506-20

GR07.506-10, GR07.506-20, GR07.506-30

BDD_GR07.510-20

GR07.510-10, GR07.510-20, GR07.510-30

BDD_GR07.516-20

GR07.516-10, GR07.516-20, GR07.516-30

  • * = M5 x 4 depth
Item no.GR07.506-10GR07.506-20GR07.506-30GR07.510-10GR07.510-20GR07.510-30GR07.516-10GR07.516-20GR07.516-30
A [mm]49.559.569.556.566.576.5667686
B [mm]425262495969586878
C [mm]142430142430203040
D [mm]152535152535102030
L [mm]102030102030102030

+Accessories