Oil-lubricated vacuum pumps

Oil-lubricated vacuum pumps are available form FIPA as rotary vane vacuum pumps.


Compact vacuum generators require minimal installation space, they are suited for applications that handle porous products and they achieve an extremely high vacuum level. The integrated oil recovery system minimizes oil vapours in the vacuum supply. An efficient damping system ensures a reduced sound pressure level.


In continuous operation, oil-lubricated rotary vane vacuum pumps by FIPA, like all other wet-running vacuum pumps, should be operated at full load (minimum vacuum level: 99.8 %) in order to prevent oil leaks.

Oil-lubricated rotary vane vacuum pumps are available with single-phase and three-phase connection. The mounting position is horizontal.


Many of the oil-lubricated vacuum pums can be used in humid or dry areas.

Product group
Suction power at 50 Hz [m³/h]
Suction power at 60 Hz [m³/h]
Final vacuum [%]

Rotary vane vacuum pumps - oil-lubricated

  • Very high final vacuum level
  • Drives with multi-range voltages
  • Especially suited for the evacuation of small closed containers
  • Efficient damping and oil recovery system prevents oil mist and reduces sound level
  • Compact and lightweight design for low space requirements or installation on moving devices (sufficient ventilation needs to be ensured)
  • Pump is cooled via fan
  • Horizontal mounting position

Technical data

Item no.DO.4C-1DO.4C-3
Suction power at 50 Hz [m³/h] 4 4
Suction power at 60 Hz [m³/h] 4.4 4.4
Final vacuum [%] 99.8 99.8
Power supply +/- 5 % at 50 Hz [V] 220 - 240 Delta: 220-255 Star: 380-440
Power supply +/- 5 % at 60 Hz [V] 220 - 240 Delta: 220-266 Star: 380-460
Current consumption at 50 Hz [A] 1 Delta: 0.7-0.8 Star: 0.4-0.46
Current consumption at 60 Hz [A] 1.1 Delta: 0.7 Star: 0,38-0.42
Rated power at 50 (60) Hz [kW] 0.12 (0.15) 0.12 (0.14)
Noise level at 50 Hz [dB(A)] 57 57
Noise level at 60 Hz [dB(A)] 59 59
Operating temperature at 50 Hz [°C] 60 - 65 60 - 65
Operating temperature at 60 Hz [°C] 65 - 70 65 - 70
Weight [kg] 5.4 5.4
Data Sheet Download datasheet Download datasheet
CAD----
Quote Quote Quote

+Ordering notes

  • Available in single-phase and three-phase designs (Index -1 to -3)
  • Included in scope of delivery: Condensate exhaust filter oil SW 40, thermal protection 130 °C (with single-phase motor)

+Notes

  • Continuous operation only under full load (min. 99.8 % vacuum), otherwise, risk of oil discharge, no gas ballast
  • For operation under moist conditions please consult FIPA

+Dimensions

  • * = 6 x vanes, FKM O-Rings, oil recirculation valve, oil mist separator, filter
  • ** = 6 x vanes, FKM O-Rings, seal, oil recirculation valve, oil mist separator, filter
  • *** = Oil mist separator, rubber washer, follower, 1 x filter cartridge, 1 x O-ring FKM

+Diagrams

BD_DO.3-DO.4_Diagramm_Saugleistung-50hz_en_Master zoom

Suction power against vacuum level at 50 Hz

BD_DO.3-DO.4_Diagramm_Saugleistung-60hz_en_Master zoom

Suction power against vacuum level at 60 Hz

+Accessories

Item no. Suitable Pre-filtersSuitable Spare-part-kits
DO.4C-1FB 5KIT-DO.4C/K***, KIT-DO.4C/G**
DO.4C-3FB 5KIT-DO.4C/K***, KIT-DO.4C/G**

Rotary vane vacuum pumps – oil-lubricated

  • Very high final vacuum level
  • Suitable for moist environments
  • Effective damping and recovery system prevents oil mist and reduces sound level
  • Innovative sealing system prevents oil recirculation at standstill under vacuum
  • Compact design and low weight
  • Horizontal mounting position

Technical data

Item no.DO.5B-1DO.5B-3
Suction power at 50 Hz [m³/h] 5 5
Suction power at 60 Hz [m³/h] 6 6
Final vacuum [%] 99 99
Gas ballast Yes Yes
Max. inlet pressure for water vapour [mbar] 30 30
Water vapor capacity [l/h] 0.11 0.11
Check valve Yes Yes
Power supply at 50 (60) Hz [V] 220 - 240 Delta: 220-255 (220-266) Star: 380-440 (380-460)
Current consumption at 50 (60) Hz [A] 1.7 - 2.1 Delta: 1.8-2.3 (1.6-2.3) Star: 1-1.3 (0.9-1.3)
Rated power at 50 (60) Hz [kW] 0.25 (0.25) 0.37 (0.45)
Noise level at 50 (60) Hz [dB(A)] 58 (60) 58 (60)
Operating temperature [°C] 65 - 75 65 - 75
Weight [kg] 13 11.5
Data Sheet Download datasheet Download datasheet
CAD----
Quote Quote Quote

+Ordering notes

  • Available in single-phase and three-phase designs (Index -1 or -3)
  • Included in scope of delivery: Condensate exhaust filter, gas ballast, oil SW 60, oil non-return valve

+Notes

  • Designed for continuous operation under vacuum levels of 60 % to 99 %, integrated gas ballast, water vapor tolerance

+Dimensions

  • * = O-Ring 121 FKM, filter element
  • ** = Shaft seal, 2 x O-Ring 3300 NBR, 3 x vanes, 2 x ejector, inlet shield, inlet rubber NBR, filter disk, NBR rubber for exhaust valve, 3 x copper washer, O-Ring 121 FKM, filter element, gasket, sintered filter G1/8

+Diagrams

BD_DO.5_Diagramm_Saugleistung-50hz_en_Master zoom

Suction power against vacuum level at 50 Hz

BD_DO.5_Diagramm_Saugleistung-60hz_en_Master zoom

Suction power against vacuum level at 60 Hz

+Accessories

Item no. Suitable Spare-part-kits
DO.5B-1KIT-DO.5B/G**, KIT-DO.5B/K*
DO.5B-3KIT-DO.5B/G**, KIT-DO.5B/K*

Rotary vane vacuum pumps - oil-lubricated

  • Very high final vacuum level
  • Effective damping and recovery system prevents oil mist and reduces sound level
  • Innovative sealing system prevents oil recirculation at standstill under vacuum
  • Compact design and low weight
  • Horizontal mounting position

Technical data

Item no.DO.8B-1DO.8B-3DO.12C-1DO.12C-3
Suction power at 50 Hz [m³/h] 8 8 12 12
Suction power at 60 Hz [m³/h] 9 9 14 14
Final vacuum [%] 99.8 99.8 99.8 99.8
Gas ballast -- -- Yes Yes
Max. inlet pressure for water vapour [mbar] -- -- 40 40
Water vapor capacity [l/h] -- -- 0.3 0.3
Check valve Yes Yes Yes Yes
Power supply at 50 (60) Hz [V] 220 - 240 Delta: 220-255 (220-266) Star: 380-440 (380-460) 220 - 240 Delta: 220-255 (220-266) Star: 380-440 (380-460)
Current consumption at 50 (60) Hz [A] 2.3 (2.5) Delta: 1.4-1.5 (1.5-1.4) Star: 0.8-0.86 (0.86-0.8) 3-3.6 (3.3-3.1) Delta: 1.4-1.5 (1.5-1.4) Star: 0.8-0.86 (0.86-0.8)
Rated power at 50 (60) Hz [kW] 0.37 (0.45) 0.25 (0.3) 0.45 (0.55) 0.37 (0.45)
Noise level at 50 (60) Hz [dB(A)] 58 (60) 58 (60) 60 (62) 60 (62)
Operating temperature [°C] 65 - 75 65 - 75 65 - 75 65 - 75
Weight [kg] 10 9 14 12.5
Data Sheet Download datasheet Download datasheet Download datasheet Download datasheet
CAD--------
Quote Quote Quote Quote Quote

+Ordering notes

  • Available in single-phase and three-phase designs (Index -1 or -3)
  • Included in scope of delivery: Condensate exhaust filter, gas ballast (with DO.12C-3), oil SW 40, oil non-return valve

+Notes

  • DO.8: Continuous operation only under full load (min. 99.8 % vacuum), otherwise, risk of oil discharge, no gas ballast
  • DO.8: For operation under moist conditions please consult FIPA
  • DO.12: Designed for continuous operation for vacuum levels between 60 % and 99.9 %, gas ballast available, can tolerate water vapor

+Dimensions

BDD_DO.8

DO.8B-1, DO.8B-3

BDD_DO.12

DO.12C-1, DO.12C-3

  • * = FKM O-Rings, outlet filter
  • ** = 3 vanes, FKM-O rings, seal, valve, inlet and outlet filter, oil recirculation valve
  • *** = FKM O-rings, oil mist separator
  • **** = 3 vanes, FKM o-rings, seal, filter, oil mist separator, spring

+Diagrams

BD_DO.8-DO.12A_Diagramm_Saugleistung-50hz_en_Master zoom

Suction power against vacuum level at 50 Hz

BD_DO.8-DO.12A_Diagramm_Saugleistung-60hz_en_Master zoom

Suction power against vacuum level at 60 Hz

+Accessories

Item no. Suitable Pre-filtersSuitable Spare-part-kits
DO.8B-1FB 10KIT-DO.8B/G**, KIT-DO.8B/K*
DO.8B-3FB 10KIT-DO.8B/G**, KIT-DO.8B/K*
DO.12C-1FB 20KIT-DO.12C/G****, KIT-DO.12C/K***
DO.12C-3FB 20KIT-DO.12C/G****, KIT-DO.12C/K***

Rotary vane vacuum pumps - oil-lubricated

  • Very high level of final vacuum
  • Suitable for moist environments
  • Effective damping and recovery system prevents oil mist and reduces sound level
  • Innovative sealing system prevents oil recirculation at standstill under vacuum
  • DO.20C-3 und DO.25C-3: Universal motor according to IE class 2 with wide voltage spectrum for worldwide use
  • Horizontal mounting position

Technical data

Item no.DO.20C-1DO.20C-3DO.25C-1DO.25C-3
Suction power at 50 Hz [m³/h] 20 20 25 25
Suction power at 60 Hz [m³/h] 24 24 29 29
Final vacuum [%] 99.8 99.8 99.95 99.95
Gas ballast Yes Yes Yes Yes
Max. inlet pressure for water vapour [mbar] 15 15 40 40
Water vapor capacity [l/h] 0.25 0.25 0.7 0.7
Check valve Yes Yes Yes Yes
Power supply at 50 (60) Hz [V] 220 - 240 Delta: 175-260 (200-300) Star: 300-450 (346-520) 220 - 240 Delta: 230 (265) Star: 400 (460)
Current consumption at 50 (60) Hz [A] 4-4.1 (5.7-5.6) Delta: 3.4-3.3 (4.1-3.3) Star: 2.0-1.9 (2.4-1.9) 3 (3) Delta: 3.0 (3.0) Star: 1.7 (1.7)
Rated power at 50 (60) Hz [kW] 0.75 (0.9) 0.75 (0.9) 0.75 (0.9) 0.75 (0.9)
Noise level at 50 (60) Hz [dB(A)] 64 (67) 64 (67) 62 (65) 62 (65)
Operating temperature [°C] 60 - 70 60 - 70 80 - 90 80 - 90
Weight [kg] 19 17 26 25
Data Sheet Download datasheet Download datasheet Download datasheet Download datasheet
CAD--------
Quote Quote Quote Quote Quote

+Ordering notes

  • Available in single-phase and three-phase designs (Index -1 or -3)
  • Included in scope of delivery: Gas ballast, oil non-return valve, oil SW 40 (with DO.20), oil SW 60 (with DO.25)

+Notes

  • DO.20: Designed for continuous operation for vacuum level between 60 % and 99.8 %, gas ballast available, can tolerate water vapor
  • DO.25: Designed for continuous operation for vacuum level between 60 % and 99.95 %, gas ballast available, can tolerate water vapor

+Dimensions

BDD_DO.20

DO.20C-1, DO.20C-3

BDD_DO.25

DO.25C-1, DO.25C-3

  • * = FKM O-rings, oil mist separator
  • ** = 3 x vanes, FKM O-rings, valve, filter, copper washer G1/8''
  • *** = FKM and NBR O-rings, outlet filter
  • **** = 2x FKM shaft seals, FKM O-rings, filter, valve, 3 vanes

+Diagrams

BD_DO.20-DO.25_Diagramm_Saugleistung-50hz_en_Master zoom

Suction power against vacuum level at 50 Hz

BD_DO.20-DO.25_Diagramm_Saugleistung-60hz_en_Master zoom

Suction power against vacuum level at 60 Hz

+Accessories

Item no. Suitable Pre-filtersSuitable Spare-part-kits
DO.20C-1FB 20KIT-DO.20C/G**, KIT-DO.20C/K*
DO.20C-3FB 20KIT-DO.20C/G**, KIT-DO.20C/K*
DO.25C-1FB 25KIT-DO.25C/G****, KIT-DO.25C/K***
DO.25C-3FB 25KIT-DO.25C/G****, KIT-DO.25C/K***

Rotary vane vacuum pumps - oil-lubricated

  • Very high level of final vacuum
  • Suitable for moist environments
  • Effective damping and recovery system with by-pass and novel float valve guarantees oil-free exhaust air
  • Innovative sealing system prevents oil recirculation at standstill under vacuum
  • Universal motor according to IE class 2 with wide voltage spectrum for worldwide use
  • Horizontal mounting position

Technical data

Item no.DO.40C-1DO.40C-3DO.60C-1DO.60C-3
Max. inlet pressure for water vapour [mbar] 14 14 14 14
Final vacuum [%] 99.9 99.9 99.9 99.9
Suction power at 50 Hz [m³/h] 40 40 60 60
Suction power at 60 Hz [m³/h] 48 48 72 72
Gas ballast Yes Yes Yes Yes
Water vapor capacity [kg/h] 0.5 0.5 0.7 0.7
Check valve Yes Yes Yes Yes
Power supply at 50 (60) Hz [V] 220 - 240 Delta: 230 (265) Star: 400 (460) 220 - 240 Delta: 230 (265) Star: 400 (460)
Current consumption at 50 (60) Hz [A] 4.1 (2.37) Delta: 4.1 (4.3) Star: 2.37 (2.49) 5.76 (3.33) Delta: 5.76 (5.72) Star: 3.33 (3.31)
Rated power at 50 (60) Hz [kW] 1.1 (1.35) 1.1 (1.35) 1.5 (1.8) 1.5 (1.8)
Noise level at 50 (60) Hz [dB(A)] 64 (66) 64 (66) 66 (68) 66 (68)
Operating temperature [°C] 65 - 70 65 - 70 70 - 75 70 - 75
Weight [kg] 46.5 42 46 44
Data Sheet Download datasheet Download datasheet Download datasheet Download datasheet
CAD--------
Quote Quote Quote Quote Quote

+Ordering notes

  • Available in single-phase and three-phase designs (Index -1 or -3)
  • Included in scope of delivery: Condensate exhaust filter, gas ballast, oil SW 60, oil non-return valve

+Notes

  • Designed for continuous operation for vacuum level between 60 % to 99,9 %, gas ballast available, can tolerate water vapor

+Dimensions

  • * = Seal, Oil mist separator, Oil filter
  • ** = 2 x FKM shaft seals, FKM O-rings, seals, filter, 3 x vanes

+Diagrams

BD_DO.40-DO.60_Diagramm_Saugleistung-50hz_en_Master zoom

Suction power against vacuum level at 50 Hz

BD_DO.40-DO.60_Diagramm_Saugleistung-60hz_en_Master zoom

Suction power against vacuum level at 60 Hz

+Accessories

Item no. Suitable Pre-filtersSuitable Spare-part-kits
DO.40C-1FB 30KIT-DO.40C/G**, KIT-DO.40C/K*
DO.40C-3FB 30KIT-DO.40C/G**, KIT-DO.40C/K*
DO.60C-1FB 30KIT-DO.60C/G**, KIT-DO.60C/K*
DO.60C-3FB 30KIT-DO.60C/G**, KIT-DO.60C/K*

Rotary vane vacuum pumps - oil-lubricated

  • Very high final vacuum
  • Suitable for moist environments
  • Effective damping and recovery system with by-pass and novel float valve guarantees oil-free exhaust air
  • Innovative sealing system prevents oil recirculation at standstill under vacuum
  • Elastic motor coupling effectively absorbs shocks
  • Universal motor according to IE class 2 with wide voltage spectrum for worldwide use
  • Horizontal mounting position

Technical data

Item no.DO.105C-3DO.150C-3DO.205C-3DO.305C-3
Suction power at 50 Hz [m³/h] 105 150 205 305
Suction power at 60 Hz [m³/h] 125 180 245 365
Final vacuum [%] 99.95 99.95 99.95 99.95
Gas ballast Yes Yes Yes Yes
Max. inlet pressure for water vapour [mbar] 30 25 25 25
Water vapor capacity [l/h] 2.2 2.5 3.5 5
Check valve Yes Yes Yes Yes
Power supply at 50 (60) Hz [V] Delta: 230 (265) Star: 400 (460) Delta: 230 (265) Star: 400 (460) Delta: 230 (265) Star: 400 (460) Delta: 230 (265) Star: 400 (460)
Current consumption at 50 (60) Hz [A] Delta: 8.8 (9.0) Star: 5.1 (5.2) Delta: 8.8 (9.0) Star: 5.1 (5.2) Delta: 20 (20.3) Star: 11.6 (11.7) Delta: 27.7 (26.8) Star: 16 (15.5)
Rated power at 50 (60) Hz [kW] 2.2 (2.7) 3 (3.6) 4 (4.8) 5.5 (6.5)
Noise level at 50 (60) Hz [dB(A)] 68 (70) 70 (72) 72 (74) 74 (76)
Operating temperature [°C] 75 - 85 75 - 85 70 - 80 75 - 85
Weight [kg] 70 82 154 164
Data Sheet Download datasheet Download datasheet Download datasheet Download datasheet
CAD--------
Quote Quote Quote Quote Quote

+Ordering notes

  • Scope of supply: Condensate exhaust filter, gas ballast, oil non-return valve, oil SW 100

+Notes

  • Designed for continuous operation for vacuum level between 60 % to 99.95 %, gas ballast available, can tolerate water vapor

+Dimensions

BDD_DO.105-DO.150

DO.105C-3, DO.150C-3

BDD_DO.205

DO.205C-3, DO.305C-3

  • * = Rubber link, seals, 3 vanes, FKM shaft seal, FKM O-rings, oil filter with bypass
  • ** = Rubber link, FKM and NBR O-rings, 3 x vanes, oil recirculation pipe, gas ballast pipe, filters, oil inspection glas
  • *** = Oil filter with bypass valve, exhaust filter, gasket

+Diagrams

BD_DO.105-DO.205_Diagramm_Saugleistung-50hz_en_Master zoom

Suction power against vacuum level at 50 Hz

BD_DO.105-DO.205_Diagramm_Saugleistung-60hz_en_Master zoom

Suction power against vacuum level at 60 Hz

+Accessories

Item no. Suitable Pre-filtersSuitable Spare-part-kits
DO.105C-3FB 40KIT-DO.105C/K***, KIT-DO.105C/G*
DO.150C-3FB 50, FB 60KIT-DO.150C/K***, KIT-DO.150C/G*
DO.205C-3FB 50, FB 60KIT-DO.205C/K***, KIT-DO.205C/G**
DO.305C-3FB 60KIT-DO.305C/K***, KIT-DO.305C/G**