FIPA Service Hotline

00 800 - 22 553 472

Solenoid valves for compressed air

FIPA offers 3/2-way and 5/2-way electromagnetic valves for controlling compressed air in automation systems.

Compressed air in automation systems can be ideally controlled using electromagnetic valves, also called solenoid or seat valves.

The most common application for 3/2-way electromagnetic valves is the compressed air control of vacuum generators such as ejectors. They are also perfect for installing in vacuum grippers with integrated ejectors.

The blow-off function can also be controlled using direct-controlled 5/2-way electromagnetic valves, thereby achieving extremely short depositing times in handling applications with ejectors without integrated valve technology.

Solenoid valves for compressed air

Indirectly controlled, with spring reset

solenoid-valves-compressed-air-fipa-36060 Enlarge picture
solenoid-valves-compressed-air-fipa-36061 Enlarge picture
  • Suitable for compressed air
  • 36.060: For use e.g. to increase cycle times for ejectors without valve technology
    Example: Vacuum and blow-off control for multi-chamber ejectors e.g. 65.410
    - 1x compressed air vacuum generation
    - 1x compressed air blow-off
  • 36.061: For use e.g. as a blow-off control valve for 3/2-way vacuum valves
  • Robust and lightweight housing

Technical data

Item no.36.06036.061
Nominal width [mm] 6 6
Nominal flow rate at 6 bar [m³/h] 37.2 37.2
Control pressure [bar] 2.5 - 10 2.5 - 10
Design 5/2 3/2
Supply voltage [VDC] 24 24
Duty ratio [%] 100 100
Max. Power consumption [W] 3.8 3.8
Protection class IP65 IP65
Material High resistant, fiber-glass reinforced Polyarylamide (IXEF®) High resistant, fiber-glass reinforced Polyarylamide (IXEF®)
Operating temperature [°C] -5 - 50 -5 - 50
Weight [g] 180 260
Data Sheet Download datasheet Download datasheet
Quote Quote Quote

+Ordering notes

  • Included in scope of delivery: Coil and DIN plug 10.006 for 24 VDC, IP65
  • Spare part kits available on request






  • * = Assignment see wiring diagrams
Item no.36.06036.061
A [mm]3535
B [mm]2525
C [mm]153136
D [mm]10083
Ø d1 [mm]4.254.25
E [mm]1818
F [mm]1616
H [mm]3820

+Wiring diagrams

+Application example: Usage of 36.061 as control valve to activate blow-off of 3/2-way vacuum valves (here: Valve 36.520)