Compact ejectors

Ejectors with air saving function EKPP

Ejectors with air saving function EKPP


Energy saving function by integrated pressure control


  • Energy saving function through automatic pressure regulation
    - Full performance starting from 4 bar supply pressure
    - In between 4 - 8 bar supply pressure the ejector operates at 3,5 bar 
    - Air saving potential increases with difference between supply pressure and operation pressure
    - This saves up to 50 % energy with every workpiece - no matter if dense or porous
  • Significant reduction of sound level as exhaust pressure is independent of system pressure
  • Optimized open silencer reduces noise level up to 30 dBA and operates fully maintenance-free
Technical Data
Item no.EKPP.60x12EKPP.60x15EKPP.60x20EKPP.60x25EKPP.60x30
Nozzle diameter [mm]1,21,52,02,53,0
Suction power [Nl/min]72110189275385
Air consumption [Nl/min]6597179260385
Final vacuum [%]6060606060
Optimal feed pressure [bar]4 - 84 - 84 - 84 - 84 - 8
Operating pressure [bar]3,53,53,53,53,5
Usage temperature [°C]10 - 6010 - 6010 - 6010 - 6010 - 60
Data Sheet
Quotation
 
> Shopping cart
Ejectors with air saving function EKPP
Ejectors with air saving function EKP

Ejectors with air saving function EKP


Energy saving function by integrated pressure control


  • Energy saving function through automatic pressure regulation
    - Full performance starting from 4 bar supply pressure
    - In between 4 - 8 bar supply pressure the ejector operates at 3,5 bar 
    - Air saving potential increases with difference between supply pressure and operation pressure
    - This saves up to 50 % energy with every workpiece - no matter if dense or porous
  • Significant reduction of sound level as exhaust pressure is independent of system pressure
  • Optimized open silencer reduces noise level up to 30 dBA and operates fully maintenance-free
  • Integrated vacuum valve for vacuum control
  • Integrated blow-off function for fast duty cycles
  • Blow-off flow manually adjustable
Technical Data
Item no.EKP.60x12EKP.60x15EKP.60x20EKP.60x25EKP.60x30
Nozzle diameter [mm]1,21,522,53
Suction power [Nl/min]72110189275385
Air consumption [Nl/min]6597179200385
Final vacuum [%]6060606060
Optimal feed pressure [bar]4 - 84 - 84 - 84 - 84 - 8
Operating pressure [bar]3,53,53,53,53,5
Usage temperature [°C]10 - 6010 - 6010 - 6010 - 6010 - 60
Protection classIP65IP65IP65IP65IP65
Control voltage24 V DC (adjusted) ± 10% 24 V DC (adjusted) ± 10% 24 V DC (adjusted) ± 10% 24 V DC (adjusted) ± 10% 24 V DC (adjusted) ± 10%
Current consumption for vacuum and blow-off feature [mA]30 (0,7 W)30 (0,7 W)30 (0,7 W)30 (0,7 W)30 (0,7 W)
Data Sheet
Quotation
 
> Shopping cart
Ejectors with air saving function EKP
Compact ejectors EKP-LS

Compact ejectors EKP-LS


  • Massive reduction of air consumption: automatic shut-off, when designated vacuum level is reached
  • Integrated check valve to keep set vacuum level
  • Vacuum generation reactivated when minimum threshold level is reached
  • Ejector particularily designed for handling dense workpieces
  • Model range for 50 %, 75 % and 90 % max. vacuum level
  • Integrated electronic blow-off function for release of workpiece and fast cycle times
  • Maximum process safety as vacuum level is maintained in case of power failure
  • Straight-line and contamination-proof design, no filter required
Technical Data
Item no.EKP.50x25-LSEKP.75x25-LS EKP.90x25-LS
Nozzle diameter [mm]2,52,52,5
Suction power [Nl/min]360240200
Air consumption at 4 bar [Nl/s]6,55,54,5
Final vacuum [%]507590
Feed pressure [bar]2 - 62 - 62 - 6
Optimal feed pressure [bar]444
MediumUnlubricated, filtered airUnlubricated, filtered airUnlubricated, filtered air
Switching logicPNP, ON/OFF, NO/NC, adjustable HysteresisPNP, ON/OFF, NO/NC, adjustable HysteresisPNP, ON/OFF, NO/NC, adjustable Hysteresis
Usage temperature [°C]0 - 600 - 600 - 60
Control voltage24 V DC (adjusted) ± 10% 24 V DC (adjusted) ± 10% 24 V DC (adjusted) ± 10%
Data Sheet
Quotation
> Shopping cart
Ejectors with air saving function EMM

Ejectors with air saving function EMM


Energy saving function by integrated pressure control


  • Energy saving function through automatic pressure regulation
    - Full performance starting from 4 bar supply pressure
    - In between 4 - 8 bar supply pressure the ejector operates at 3,5 bar
    - Air saving potential increases with difference between supply pressure and operation pressure
    - This means up to 50% less energy consumption with every workpiece - no matter if dense or porous
  • Integrated blow-off function for fast duty cycles
  • Blow-off flow manually adjustable
  • LED Display to set and monitor vacuum leves
  • Very compact design with integrated open silencer reduces noise level up to 30 dBA and operates fully maintenance-free
Technical Data
Item no.EMM.60x10EMM.60x12EMM.60x14EMM.90x10EMM.90x12
Nozzle diameter [mm]1,01,21,41,01,2
Suction power [Nl/min]3872922945
Air consumption [Nl/min]4465904465
Final vacuum [%]6060609090
Optimal feed pressure [bar]4 - 84 - 84 - 84 - 84 - 8
Operating pressure [bar]3,53,53,53,53,5
Usage temperature [°C]10 - 6010 - 6010 - 6010 - 6010 - 60
Protection classIP65IP65IP65IP65IP65
Control voltage24 V DC (adjusted) ± 10% 24 V DC (adjusted) ± 10% 24 V DC (adjusted) ± 10% 24 V DC (adjusted) ± 10% 24 V DC (adjusted) ± 10%
Current consumption for vacuum and blow-off feature [mA]30 (0,7 W)30 (0,7 W)30 (0,7 W)30 (0,7 W)30 (0,7 W)
Data Sheet
Quotation
 
> Shopping cart
Ejectors with air saving function EMM
Ejectors with air saving function EMA

Ejectors with air saving function EMA


Double energy efficient by integrated pressure control and electronic air saving function


  • Handling of dense workpieces
  • Integrated electronic air-saving system (LSA)
    - Reduces operating costs from 60 up to 97 % with dense workpieces
    - Automatically adjusts to workpiece type (activiation with dense workpieces, deactivation with higher porosity or uneven surfaces)
  • Integrated pressure control
    - Automatic pressure regulation to 3,5 bar constant
    - Significantly reduces operating costs up to 50 % also with porous workpieces
    - Air saving potential increases with difference between supply pressure and operation pressure
  • Available versions normally open (NO) or normally closed (NC)
  • Reduced sound level through integrated open silencer ( ~ 68 dBA without automatic air-saving system, ~ 0 dBA with active automatic air-saving system)
  • Dirt-proof construction, no filter required
  • Easy setting via keyboard, operational status and fault detection via display
Technical Data
Item no.EMA.90x10EMA.90x12EMA.90x14
Nozzle diameter [mm]1,01,21,4
Suction power [Nl/min]294570
Air consumption [Nl/min]446590
Final vacuum [%]909090
Optimal feed pressure [bar]4 - 84 - 84 - 8
Working pressure [bar]3,53,53,5
Usage temperature [°C]10 - 6010 - 6010 - 60
Control voltage24 V DC (adjusted) ± 10% 24 V DC (adjusted) ± 10% 24 V DC (adjusted) ± 10%
Current consumption for vacuum and blow-off feature [mA]30 (0,7 W)30 (0,7 W)30 (0,7 W)
Protection classIP65IP65IP65
Weight [g]130130130
Data Sheet
Quotation
> Shopping cart
Ejectors with air saving function EKP-LSE

Ejectors with air saving function EKP-LSE


Double energy efficient by electronic air saving function and integrated pressure control


  • Handling dense workpieces
  • Integrated electronic air-saving system
    - Reduces operating costs from 60 up to 90 %
    - When upper vacuum level set is reached (workpiece gripped), air saving function automatically shuts off the vacuum generator
    - When vacuum level has dropped to set lower threshold, vacuum generation is re-activated until upper vacuum level is reached again 
    - Integrated check valve keeps vacuum level set after vacuum generation is shut off
  • Integrated pressure control
    - Automatic pressure regulation to 4 bar reduces air consumption also during vacuum generation
    - Additional air saving potential increases with difference between feed and operation pressure
  • Integrated blow-off function for fast duty cycles
  • Blow-off flow manually adjustable
  • Safety function in the event of a power failure (Function NO) as integrated check valve keeps vacuum
  • Reduced sound level through integrated open silencer (~ 68 dBA without automatic air-saving system, ~ 0 dBA with active automatic air-saving system)
  • Dirt-proof construction, no filter required
  • Electric connection via 2 x M12 plug 5-pin (1 x input, 1 x output)
Technical Data
Item no.EKP.90x30-LSE
Nozzle diameter [mm]3
Suction power [Nl/min]245
Air consumption at 4 bar [Nl/s]6,4
Final vacuum [%]90
Feed pressure [bar]5 - 7
Working pressure [bar]4
Usage temperature [°C]10 - 60
Control voltage24 VDC
Protection classIP65
MediumUnlubricated, filtered air
Data Sheet
Quotation
> Shopping cart